Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured
Thermo Fisher Scientific Dionex HPLC System-working configured

Thermo Fisher Scientific Dionex HPLC System-working configured

sku: 7000341
1 In Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : EU
€15,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Thermo Scientific
  • Model Dionex
  • Serial -
  • Weight 130
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 120×80×123 in
  • Shipping Type Freight
  • Item Condition Pre-owned
  • Manufacturing Date N/A

Thermo Dionex Ultimate 3000 HPLC System - working & configured

Comes with the following components:

TCC-3000SD Standard Thermostatted Column Compartment

FLD-3400 RS Dual-PMT Fluorescence Detectors

LPG-3400RS Rapid Separation Quaternary Pump 

WPS-3000TPL RS Well Plate Autosampler

 

TCC-3000SD Standard Thermostatted Column Compartment

Catalog number: 5730.0010

Ensure the consistency of your retention times with accurate and precise temperature control of standard flow rate applications. The Thermo Scientific Dionex UltiMate TCC-3000SD Standard Thermostatted Column Compartments supports methods at temperatures from 5° to 80°C. Optional columns switching valves (field upgrade) let you take advantage of application switching or parallel and tandem two-dimensional liquid chromatography (2D-LC) to improve your separations and increase productivity with x2 dual technology.

Description TCC-3000 SD Thermostatted Column Compartment
For Use With (Equipment) UltiMate 3000 SD Series
Type Standard Thermostatted Column Compartment
Voltage 150 V
Recommended Eluent Preheater Volume 2 μL
GLP Features Dionex AutoQ routines for Instrument QualificationColumn Identification System for four columns
I/O Interfaces 2 digital inputs, 2 programmable relay outputs
Cool-Down Time 15 min.
Max. Column Length 30 cm
Heat Up Time 15 min.
Column Capacity Up to 12 columns, depending on column length; Max. column length: 30 cm
Max. No. of Switching Valves Up to 2 Valves: 2-position/6- or 10-port, 6-position/7-port
PC Connection USB
Temperature Accuracy ±0.5°C
Temperature Range 5°C to 80°C
Weight (Metric) 12.6 kg
   

 

FLD-3400 RS Dual-PMT Fluorescence Detectors

Catalog number: 5078.0025

Develop highly selective methods for trace analytes or novel molecules with sensitivity three to six orders of magnitude greater than UV detection. The Thermo Scientific™ Dionex™ UltiMate™ 3000 Fluorescence Detectors offer four channel acquisition at up to 200Hz so you can optimize quantification on the most sensitive channel and single-channel detection at up to 100Hz. 2D or 3D synchro, excitation, emission scans, zero order mode, or multichannel acquisition offer flexibility for method development or routine sample characterization. A variable emission filter allows real-time, compound-related sensitivity optimization.

 

Description FLD-3400 RS Rapid Separation Fluorescence Detector with Dual-PMT, four channels, without flow cell
Data Collection Rate 200 Hz
Detection Mode 4 Channels
Detector Type High-Sensitivity Fluorescence
Type Fluorescence Detector
Display LCD Monitor
Filter Variable
Flow Cell Max. Pressure 290 psi
Flow Cell Thermostatting 15°C Above Ambient -50°C
Flow Cell Volume 8 μL
Flow Rate Analytical to Semi-Prep
GLP Features Automatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
Lamp Xenon Flash Lamp
Lamp Pulse Frequency 300 Hz
No. of Channels 4
PC Connection USB
Sensitivity >550 ASTM
Spectral Bandwidth 20 nm
Temperature Control Yes
Wavelength Accuracy ±2 nm
Wavelength Range 200 to 880 nm
Wavelength Repeatability ±0.2 nm
Wavelength Switching Time <250 ms
Weight (Metric) 18 kg

 

LPG-3400RS Rapid Separation Quaternary Pump

Catalog number: 5040.0036

For the highest degree of flexibility with solvent proportioning in UHPLC or conventional LC, the Thermo Scientific™ Dionex™ UltiMate™ LPG-3400RS Rapid Separation Quaternary Pump supports ternary and quaternary gradients over an industry-leading flow-pressure footprint. It supports the use of up to four solvents at up to 15,000 psi (100 MPa) and a recommended flow rate range from 200µL to 8.0mL/min. with excellent flow stability. This pump adapts easily to multiple fast routine applications or method development in the pharmaceutical, food and beverage and environmental industries.

 

Description LPG-3400 RS Quaternary RS Pump
Biocompatible Version Yes
Flow Accuracy ±0.1%
Flow Precision <0.05% RSD or <0.01 min SD, whichever is greater
Gradient Formation Low-Pressure Proportioning
Max. Flow Rate 8 mL/min.
Pressure Range 2 to 103.4 MPa up to 5 mL/min; 2 to 80 MPa up to 8 mL/min
Type Serial Dual-Piston Quaternary Rapid Separation Pump
Emission Sound Pressure Level <70 dB(A) in 1-m-distance
For Use With (Equipment) 15-Pin D-Sub Connector for Solvent Rack/Degasser Connection
GLP Features Full support of Thermo Scientific Dionex AutoQ instrument qualification, qualification status and system wellness monitoring. All system parameters are logged in the Chromeleon Audit Trail.
Gradient Delay Volume 325-1840 µL (Depending on the SpinFlow mixer configuration)Default: 690 µL
I/O Interfaces 2 digital inputs, 2 relay outputs
Min. Flow Rate 0.001 mL/min. (Recommended: 0.1 mL/min.)
No. of Eluent Lines 4
Operating Principle Serial dual-piston
PC Connection USB for PC connection, USB hub with 3 sockets integrated
Pressure Ripple Typically: <0.2 MPa or <1% whichever is greater
Proportioning Accuracy ±0.5% (full scale)
Proportioning Precision <0.15% SD
Solvent Degassing Built-in, 4 channels
Overall Width (English) 16.5 in.
Overall Width (Metric) 42 cm
Overall Height (English) 6.3 in.
Overall Height (Metric) 16 cm
Overall Depth (English) 20 in.
Overall Depth (Metric) 51 cm
Weight (English) 29.8 lb.
Weight (Metric) 13.5 kg
Voltage 100-120 V, 60 Hz; 200-240 V, 50 Hz
Frequency 100-120 V, 60 Hz; 200-240 V, 50 Hz

 

WPS-3000TPL RS Well Plate Autosampler

Catalog number: 5826.0020

Upgrade to the Thermo Scientific Vanquish Neo UHPLC System. Thermo Scientific Dionex UltiMate WPS-3000TPL/PL RSLCnano Well Plate Autosamplers have been discontinued and have been replaced by the optimized Vanquish Neo UHPLC System. Service, spare parts and consumables for the Dionex UltiMate WPS-3000TPL/PL RSLCnano Well Plate Autosamplers are still available through the normal channels. Please contact your local representative to discuss your system requirements.

 

For Use With (Equipment) UltiMate 3000 RSLCnano Systems
Type Rapid Separation Pulled-Loop Nano/Cap Thermostatted Well Plate Autosampler
Injection Cycle Time <30 sec.
Injection Volume Precision <0.4%
Injection Volume Range 0.01 to 500 µL
Injection Type Pulled Loop
Sample Capacity 3 Racks or Well Plates
Max. Pressure 9000 psi (620 bar)
Biocompatible Version No
Linearity >0.9995
Voltage 100 to 120 V
Weight (Metric) 22.7 kg
Description WPS-3000 TPL RS Rapid Separation Pulled-Loop Nano/Cap Thermostatted Well Plate Autosampler