Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack
Thermo Scientific  Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack

Thermo Scientific Vanquish HLPC System, Column+Sampler+Pump+Solvent Rack

sku: 7000504
Out Of Stock
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : EU
€30,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Thermo Scientific
  • Hertz 50Hz/60Hz
  • Model Vanquish
  • Serial -
  • Weight 103
  • Voltage 240V
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 120×80×100 in
  • Shipping Type Freight
  • Item Condition Pre-owned
  • Manufacturing Date -

Thermo Scientific

Vanquish HLPC System

includes Column, DAD Detector, Sampler & Binary Pump

***Please check the photos to see all the details of our product***

Includes the following components:

  • Column Compartment H - VH-C10

  • Vanquish Split Sampler FT - VF-A10

  • Vanquish Binary Pump F - VF-P10

  • Vanquish Diode Array Detector FG (no flow cell) - VF-D11

     

    Vanquish Column Compartment H

VH-C10-A-03

Control your separation temperature with confidence using Thermo Scientific Vanquish Column Compartments. The unique combination of active and/or passive eluent pre-heating and two column thermostatting modes—still and forced air—available in Vanquish Column Compartments H and C, ensures reliable matching of the eluent and column temperature for superior UHPLC performance and allows for easy LC method transfer. Vanquish Column Compartment N supports advanced low-flow applications as well as capillary and micro-flow direct injection applications in the Thermo Scientific Vanquish Neo UHPLC system.

Description Vanquish Column Compartment H
For Use With (Equipment) Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
Type Column Compartment
Column Capacity 2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range 5 °C (max. 18 K below ambient) – 120 °C
Unit Size Each

Vanquish Split Sampler FT

VF-A10-A-02

Combine excellent injection precision with huge sample capacity with Thermo Scientific Vanquish Split Samplers. These samplers employ high-throughput performance to deliver the highest possible confidence in peak identification and quantitation. They provide unsurpassed sample dosing precision and are optimized for ruggedness and uptime, even under system pressures of up to 1500 bar (22,000 psi) and challenging eluent conditions. Now you can record UHPLC data over several days unattended, without running out of samples.

Injection Cycle Time Down to 8 sec. depending on separation conditions
Injection Volume Precision <0.25% area RSD for 1 µL (caffeine in water); Typically <0.5% area RSD for 0.5 µL (caffeine in water)
Injection Volume Range 0.01 to 25 µL, min. step 0.01 µL; Optional: 0.01 to 100 µL
Injection Type Split Loop
Biocompatible Version Yes
PC Connection USB 2.0; 3-port-HUB to connect further Vanquish modules
Description Vanquish Split Sampler FT
Carryover <0.002% with caffeine
Temperature Range Sample compartment: 4°C to 40°C
Dimensions (L x W x H) 290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit Size Each

Vanquish Binary Pump F

VF-P10-A-01

Achieve precise and reproducible nano-, capillary-, micro- or analytical-flow analysis with Thermo Scientific Vanquish binary pumps. These pumps support pressures up to 1500 bar and include Thermo Scientific SmartFlow or Thermo Scientific ProFlow XR technology, so you can find the binary pump perfect for your requirements.

Description Vanquish Binary Pump F
Gradient Formation High-Pressure Gradient Proportioning
Max. Flow Rate 8 mL/min.
Pressure Range 2 to 103 MPa (20 to 1034 bar, 290 to 15,000 psi)
Type Binary Pump
Min. Flow Rate 0.001 mL/min.
Unit Size Each

Vanquish Diode Array Detector FG

(flow cell not included)

VF-D11-A-01

Get the best performance, reliability, and flexibility in HPLC and UHPLC detection with Thermo Scientific Vanquish Diode Array Detectors (DAD) and Multiple Wavelength Detectors (MWD). These detectors offer excellent linearity and optimized noise performance, and feature an ultra-wide dynamic range to allow detection of highly concentrated main compounds alongside trace-level impurities.

In addition, the Vanquish DAD HL uses Thermo Scientific LightPipe technology to achieve the best signal-to-noise performance through a combination of low baseline noise, a very long light path, and minimal dispersion.

Description Vanquish Diode Array Detector FG
Data Collection Rate Up to 250 Hz
Detection Mode UV-vis Detection (Up to 10 Channels)
Detector Type Single-Beam
Type Diode Array Detector
Drift < 1 mAU/hour at 254 nm
Flow Cell Volume Standard, path length 10 mm (13 µL, SST)
Standard, biocompatible, path length 10 mm (13 µL, PEEK)
Semi-analytical, path length 7 mm (5 µL, SST)
Semi-micro, pathlength 7 mm (2.5 µL, SST)
Semi-micro, biocompatible, path length 7 mm (2.5 µL, titanium)
Diagnostic cell
GLP Features Predictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
Lamp Deuterium lamp, tungsten lamp
Linearity < 5% at 2.2 AU (typically < 5% at 2.7 AU)
Max. Cell Operating Pressure Standard biocompatible: 5 MPa (50 bar, 720 psi)
Other flow cells: 12 MPa (120 bar, 1740 psi)
Noise <± 6 µAU at 254 nm (standard flow cell, bandwidth: 4 nm, slit width: wide, time constant: 2 sec)
No. of Channels 10 + 3D field
PC Connection USB 2.0; 3-port HUB to connect further Vanquish modules
Photodiode Array 1024 element
Safety Features Power-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit Width Settable: Wide, narrow
Spectral Bandwidth Pixel resolution: 0.6 nm (average)
Temperature Range 5 to 35°C; 20 to 80% RH (non-condensing)
Validation Functions Internal validation with holmium oxide filter
Wavelength Accuracy ± 1 nm
Wavelength Range 190–800 nm
Wavelength Repeatability ± 0.1 nm
Weight (Metric) 16.3 kg
Electrical Requirements 100–240 V AC, 50/60 Hz, max. 245 W / 255 VA
Unit Size Each
 
 

 

 

 

 